Product · Load
Hidden load. From counters.
Per-class offered load on each cell, estimated from standard counters, with an interval, or a refusal when the counters cannot tell.
1
Load per class: polls, alarms, push-to-talk, video
2
Intervals on every estimate
3
“Not identifiable” when per-class counters are missing
Hands on
Three steps.
2
Counters in, load out, the ramp
Now showingA steady day 450 MHz LTE, 5 MHz (25 RB). 1,266 RTUs polled every 5 s, 156 radios, 30 cameras.
Resource blocks used, per 15 minutes · uplink · downlinkSimulated cell
Load per class, from the counters
SCADA polls 243 kbps
Alarm bursts 8 kbps
Push-to-talk 233 kbps
Event video 3.8 Mbps
Pump cards 28 kbps
Crew data 2.5 Mbps
Ramp the load
SCADA pollsholds
Alarm burstsholds
Push-to-talkholds
Event videoholds
Pump cardsholds
Headroom says
Push-to-talk breaks first, at 2× (2×–2.5×)
Load per class from the cell's own counters, ramped on the stochastic scheduler.
Beside it
Arithmetic: 7× · counter gauge: 2×
3
One clear proposal
Proposal
Push-to-talk breaks first, at 2× today's load. Arithmetic said 7×. After an outage: 33 s to reconnect, 33 s with post-quantum handshakes. Proposal: cap video so push-to-talk keeps its budget.
Proposal onlyA person decidesNot bit-true 3GPP
What it needs
- One month of LTE cell counters (standard sets)
- Endpoint list with poll intervals
- Site power autonomy and backhaul
What it is not
- Not a coverage-planning tool
- Not bit-true 3GPP
Proven, in simulation
- Names the first class to break in 75 % of held-out cells; resource-block arithmetic 17 %, today's deterministic scheduler 46 % (simulation)
- Per-class load from counters: 41 % RMS error where per-class counters exist; refuses per class on every cell without them
- On surge and storm cells the stochastic scheduler puts the break 19–37 % below arithmetic for every class, beyond the interval
- Reconnection after an outage: median 33 s classical, 35 s post-quantum on the simulated cells
Not proven
- The counter gauge (100 % ÷ today's PRB use) reads the breaking load better: 0.7× against 1.0× median error on breaking cells, and says “fits” wrongly less often (11 % against 35 %)
- Load intervals cover 71 % of true loads, not 90 %
- No real counter export used
- The uplink scheduler is new and class-level, not per flow
- KPIs on satellite-backhauled cells fall outside the standard's measurement condition
- Interference localisation not built
Works with
See Load on your asset.
Tournament run checked in. Simulation only. Not yet on a real asset. A conversation first; a data pilot when the engine has earned it.